Veris-industries A8332–8F2D Datasheet Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Veris-industries A8332–8F2D Datasheet. Veris Industries A8332–8F2D Datasheet User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
network integration
VERIS INDUSTRIES
800.354.8556
+1 503.598.4564
www.veris.com
SPECIFICATIONS
Processor ARM 7, eld upgradable rmware
LED 8 input status LEDs (red), 2 Modbus TX/RX (yellow), 1 power/alive status (green)
Protocols Modbus/ RTU
Power Supply 24VDC, 200mA (not included)
Serial Port RS-485 Modbus, 19200 or 9600 baud. N81
Inputs 8x, user selectable; 0-10V: Min/Max/Ave/Instantaneous; 4-20mA: Min/Max/Ave/Instantaneous;
Pulse: Consumption, Rate; Resistance: 0-10V: Min/Max/Ave/Instantaneous
Maximum Pulse Rate 10 Hz
Contact Closure Threshold 1 kΩ
Isolation RS-485 port is optically isolated
Operating Environment:
North America Indoor, -30° to 70°C (32° to 122°F), 0-95% RH noncondensing
DESCRIPTION
The A8332-8F2D Input Module provides a convenient way to optimize energy use
and accurately allocate costs. Add eight standard pulse and/or analog sensors to a
data acquisition network. Integrate your Veris network sensors through the A8332-
8F2D to a Veris H8822 Data Acquisition Server.
The A8332-8F2D is the rst truly exible input module that allows incorporation of
virtually any industry-standard sensor through a single device. The module can be
incorporated with cost-eective data acquisition and wireless metering solutions
such as the H8822 AcquiSuite DR server, which, as a properly integrated system,
provides high performance and low cost. This system can be incorporated into a new
or existing Building Automation System (BAS). Using the AcquiSuite data acquisition
system, users can set input types (pulse, analog, resistive, etc.), giving access to real
time resource consumption for a facility on a single board.
APPLICATIONS
Demand response program control and reporting
Cost allocation to tenants and third parties
Measurement and verication of energy savings
Converting pulse inputs from water and gas ow meters to a Modbus network
Monitoring performance of building systems (e.g., chillers, boilers, fans)
FEATURES
Network up to 8 industry-standard sensors to the AcquiSuite data
acquisition network
Universal inputs simplify setup...just connect sensors and select device output
type via the AcquiSuite or using Obvius conguration software
Check device status at a glance...LED indicators allow for fast recognition of on/
o status, TX/RX communications, and 8 input notications
Field-selectable address DIP switch...no software or PC conguration required
High reliability...nonvolatile memory retains conguration and pulse data
during power failures
All conguration information and input data is stored in non-volatile memory
to prevent data loss in the event of power failure
8 user selectable universal inputs to aggregate analog, pulse, and resistance
sensors/meters
Pulse/Analog To
Modbus® Converter
A8332-8F2D is sold as an open device.
Observe handling precautions for static sensitive
devices to avoid damage to the circuitry which
would not be covered under the factory warranty.
Year
Warranty
5
A8332-8F2D
Flexible I/O Module
A83328F2D
HQ0001805.B 01131
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Flexible I/O Module

network integrationVERIS INDUSTRIES800.354.8556+1 503.598.4564www.veris.comSPECIFICATIONSProcessor ARM 7, eld upgradable rmwareLED 8 input status

Page 2 - ORDERING INFORMATION

network integration800.354.8556+1 503.598.4564www.veris.comDIMENSIONAL DRAWINGAPPLICATION/WIRING EXAMPLE3.4”(86 mm)4.2”(106 mm)1.2”(31 mm)Modbus Energ

Commentaires sur ces manuels

Pas de commentaire