current monitoring
VERIS INDUSTRIES
800.354.8556
+1 503.598.4564
www.veris.com
Maximize Reliability
Minimize Installed Cost
FEATURES
The H809 has a low (0.75 A) minimum setpoint...eliminates the need for
multiple wraps of the conductor through the sensor even on loads as
small as 1/5 HP
H609 and H809 are small in size to t easily inside small starter enclosures
Removable mounting bracket optimizes eld versatility
Bracket on H909 can be installed in three dierent congurations...
added exibility
Status LEDs for easy setup and local indication
Adjustable trip point...precise current trip point setting
Detect belt loss and mechanical failure...ideal for fan/pump status monitoring
Easier to install than dierential pressure switches...eliminates long wiring runs
100% solid state...no moving parts to fail
5-year warranty
DESCRIPTION
Hawkeye x09 Series are high performance current switches, ideal for line voltage
loads. The devices are powered by the current being monitored.
APPLICATIONS
Detecting belt loss, coupling shear, mechanical failure, and interlocking loads
Verifying lighting circuit and other electrical service run times
Monitoring status of industrial process equipment
Monitoring status of critical motors (compressor, fuel, etc.)
SPECIFICATIONS
Sensor Power Induced from monitored conductor
Insulation Class 600VAC RMS
Frequency Range 50/60 Hz
Temperature Range -15° to 60°C (5° to 140°F)
Humidity Range 10-90% RH non-condensing
Hysteresis 10% (typical)
Terminal Block Wire Size 24-14 AWG (0.2 to 2.1 mm
2
)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Agency Approvals UL 508 open device listing; CE: EN61010-1:2001-02, CAT III, pollution degree 2, basic insulation
Do not use the LED status indicators as evidence of applied voltage
Current Switches:
Adjustable Trip Point,
High Voltage Output
Detect Belt Loss, Coupling
Shear, And Mechanical Failure
Year
Warranty
5
H709
H909
H609H809
Hx09 SERIES
TM
DETECTS BELT LOSS/COUPLING SHEAR!
DETECTS BELT LOSS/COUPLING SHEAR!
Now you can easily detect when drive belts slip, break, or pump couplings shear.
In fact, a typical HVAC motor that loses its load has a reduction of current draw
of up to 50%. That’s why our sensors are the industry standard for status.
Calibrated
Trip Point
O O
Fan/pump
On
Loss of Belt/Coupling Shear
Electrical
Failure
HQ0001755.B 01131