Installation Guide
Temperature
Z203571-0J Page 1 of 2 ©2013 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 08131
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
Other companies’ trademarks are hereby acknowledged to belong to their respective owners.
TM
NOTICE
This product is not intended for life or safety applications.
Do not install this product in hazardous or classied locations.
Read and understand the instructions before installing
this product.
Turn off all power supplying equipment before working on it.
The installer is responsible for conformance to all applicable codes.
No responsibility is assumed by Veris Industries for any consequences arising out of the
use of this material.
Product Identification
Product Overview
The TJ Series temperature sensor is designed for VAV systems. The cable is plenum rated, and the probe is stainless
steel for durability. The TJ is warranted for a period of ve years.
TJ Series
VAV Discharge Temperature Sensor
Specifications
Wiring
22 AWG; 2-wire RTD/Thermistor
Housing
Stainless Steel
LINITEMP OPTION
Input Power
5-30 VDC
Output
1 µA/ °S or 10 mV/ °C
Operating Temperature
Range
Probe: -25° to 105°C (-13 to 221°F)
Wiring side: up to 7C (167°F)
Accuracy
Calibration Error
Error over Temperature
1.5°C (3F) typical; 2.C (37°F) max. at 25°C (77°F)
1.8°C (35°F) typical; 3.0°C (3F) max. over 0° to 70°C (32° to 158°F) range;
2.0°C (35°F) typical; 3.5°C (38°F) max. over -25° to 105°C (-13° to 221°F) range
Increased cable length affects the readings of lower resistance RTDs (100R platinum RTD).
Room temperature error is documented on each unit.
Sensor Type OptionProbe Length
B = 4" (102 mm)
D = 8" (204 mm)
TJ
0 = Standard 5 ft.
cable, no QDs
1 = 1/4" Female
Quick Discon-
nects (QD)
2 = 1/4” QDs with
8 ft. lead wires
3 = 10 ft. cable,
no QDs
= Resistive
Cal Certs
0 = None
1 = 1 Point Cal Cert
2 = 2 Point Cal Cert
R
Output
B = 100R platinum, RTD
C = 1k platinum, RTD
D = 10k T2, Thermistor
E = 2.2k, Thermistor
F = 3k, Thermistor
G = 10k CPC, Thermistor
H = 10k T3, Thermistor
I = 1k Balco (Nickel-iron) RTD
J = 10k Dale, Thermistor
K = 10k w/11k shunt, Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm, Thermistor
R = 10k US, Thermistor
S = 10k 3A221, Thermistor
T = 100k, Thermistor
U = 20k “D”, Thermistor
W = 10k T2 high accuracy, Thermistor
Y = 10k T3 high accuracy, Thermistor
Z = 10k E1, Thermistor
CC = 15k, Thermistor