AIR QUALITY
VERIS INDUSTRIES
800.354.8556
+1 503.598.4564
www.veris.com
Wall CO2 Sensors,
Dual Analog Outputs
Dual Analog Outputs, Switchable
0-3/5/10 Volt/4-20 mA Output
DESCRIPTION
The CWV Series is a non-dispersive infrared sensor designed for measuring CO
2
concentration in oce and living spaces. Its 2000 ppm measurement range makes it
an ideal solution for meeting ASHRAE and other ventilation control standards.
The CWV Series features multiple output options, microprocessor-based digital
technology, and a unique self-calibration algorithm which improves long-term
stability and accuracy.
APPLICATIONS
Controlling HVAC in response to occupancy – save energy by providing
ventilation only as required
Improving tenant comfort
Schools, museums, airports, commercial buildings, etc.
OEM applications
Home automation
Big-box retail
Restaurants
C-Stores
Bid/Spec market
SPECIFICATIONS
Input Voltage 20 to 30VDC, 24VAC
Analog Output #1 4-20mA (clipped & capped) or 0-3VDC/0-5VDC/0-10VDC (jumper selectable)
Analog Output #2 4-20mA (clipped & capped) or 0-3VDC/0-5VDC/0-10VDC (jumper selectable)
Sensor Current Draw 200mA Maximum
Operating Humidity Range 0-95% RH noncondensing
Operating Temperature Range 0° to 50°C (32° to 12F)
Housing Material High impact ABS plastic
CO
2
Transmitter:
Sensor Type Non-dispersive infrared (NDIR), diusion sampling
Measurement Range 0-2000 ppm
Accuracy ±40 ppm ±5.5% of measured value
Repeatability ±30 ppm ±4.5% of measured value
Response Time <60 seconds for 90% step change
Relay Contacts 1A@30VDC, resistive; 30W max.
EMC Conformance: Low voltage directive 2006/95/EC and EMC directive 2004/108/EC.
EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1:2007 specication requirements).
Year
Warranty
1
CWV
FEATURES
Microprocessor-based design reduces long-term drift and
calibration requirements
Non-dispersive infrared technology (NDIR) repeatable to ±30 ppm ± 4.5% of
measured value...high accuracy measurements
Innovative self-calibration algorithm...easy to maintain
5-year calibration interval (recommended)
Low ambient sensitivity
Improve comfort and facilitate compliance with ASHRAE 62.1 standard
for air quality
Demand control ventilation provides reduction in energy costs...helps with
green branding initiatives
Dual analog outputs...added user convenience
LED indication for power and error detection...reduces
time spent troubleshooting
Switchable 0-3/5/10V output...increased exibility
US & European mounting holes...installation exibility
Field calibratable...reduce costly downtime
4-20mA and voltage outputs in one unit...greater versatility
CWV SERIES
HQ0001742.B 01131
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Dual Analog Outputs

AIR QUALITYVERIS INDUSTRIES800.354.8556+1 503.598.4564www.veris.comWall CO2 Sensors, Dual Analog Outputs Dual Analog Outputs, Switchable 0-3/5/10 Vo

Page 2 - AIR QUALITY

AIR QUALITY800.354.8556+1 503.598.4564www.veris.comCWVS Outputs Relay Option1 = 0-3/5/10VDC and 4-20mA2 = Dual 4-20mA 3 = Dual 0-3/5/10VDCX = None1 =

Commentaires sur ces manuels

Pas de commentaire