Installation Guide
Power Monitoring
EF, EF
TM
NV Name
NV
Num.
Function
Block
Type Units
Log
Point
Index
Propagation Control
Description
Configuration
Property
Name
Control
Type
ENERGY
nvoRealEnergy 97 TotalRealEnergy SNVT_elec_wh_f Wh 257 cpAllEnergy Throttle Real Energy Consumption (oating point value)
nvoRealEnergyInt 47 Meter SNVT_elec_kwh_l kWh, Scaled 1 cpAllEnergy Throttle Real Energy Consumption (integer value)
nvoReactEnergy 45 Meter SNVT_elec_wh_f VARh 311 cpAllEnergy Throttle Reactive Energy Consumption (oating point value)
nvoRctEnergyInt 48 Meter SNVT_elec_kwh_l kVARh, Scaled 29 cpAllEnergy Throttle Reactive Energy Consumption (integer value)
nvoAppEnergy 46 Meter SNVT_elec_wh_f Vah 309 cpAllEnergy Throttle Apparent Energy Consumption (oating point value)
nvoAppEnergyInt 49 Meter SNVT_elec_kwh_l kVAh, Scaled 27 cpAllEnergy Throttle Apparent Energy Consumption (integer value)
nvoRealEnergyPhA 50 Meter SNVT_elec_wh_f Wh 341 cpAllEnergy Throttle Real Energy Consumption, Phase A (oating point value)
nvoRealEnergyPhB 51 Meter SNVT_elec_wh_f Wh 343 cpAllEnergy Throttle Real Energy Consumption, Phase B (oating point value)
nvoRealEnergyPhC 52 Meter SNVT_elec_wh_f Wh 345 cpAllEnergy Throttle Real Energy Consumption, Phase C (oating point value)
nvoRlEnrgyPhAInt 53 Meter SNVT_elec_kwh_l kWh, Scaled 47 cpAllEnergy Throttle Real Energy Consumption, Phase A (integer value)
nvoRlEnrgyPhBInt 54 Meter SNVT_elec_kwh_l kWh, Scaled 49 cpAllEnergy Throttle Real Energy Consumption, Phase B (integer value)
nvoRlEnrgyPhCInt 55 Meter SNVT_elec_kwh_l kWh, Scaled 51 cpAllEnergy Throttle Real Energy Consumption, Phase C (integer value)
nviEnergyReset 34 Meter SNVT_switch - - - - Clears all energy accumulators to 0. To reset, set the state
eld to 1 and the value eld to greater than 0.
nvoEnrgyResetCnt 93 Meter SNVT_count - cpEnrgyResetCnt Heartbeat Count of energy accumulator resets.
nvoIntEnrgScale 95 Meter SNVT_count_inc -4 0.0001
-3 0.001
-2 0.01
-1 0.1
0 1.0
1 10.0
2 100.0
3 1000.0
4 10000.0
-
-
-
-
-
-
-
-
-
None - Scale factor for integer energy network variables. This
value is an integer between -4 and 4. Multiply integer
energy values by 10 to the power of this variable. For
example, if this variable returns -2, multiply integer
energy accumulators by 10
-2
(0.01). Only recalculated
when meter conguration is changed, so this value may
be read infrequently.
POWER
nvoRealPower 98 TotalRealPower SNVT_power_f W 261 cpAllPower Throttle Total Instantaneous Real Power
nvoReactivePower 56 Meter SNVT_power_f VAR 263 cpAllPower Throttle Total Instantaneous Reactive Power
nvoApparentPower 57 Meter SNVT_power_f VA 265 cpAllPower Throttle Total Instantaneous Apparent Power
nvoRealPowerPhA 58 Meter SNVT_power_f W 275 cpAllPower Throttle Real Power, Phase A
nvoRealPowerPhB 59 Meter SNVT_power_f W 277 cpAllPower Throttle Real Power, Phase B
nvoRealPowerPhC 60 Meter SNVT_power_f W 279 cpAllPower Throttle Real Power, Phase C
nvoReactPowerPhA 61 Meter SNVT_power_f VAR 319 cpAllPower Throttle Reactive Power, Phase A
nvoReactPowerPhB 62 Meter SNVT_power_f VAR 321 cpAllPower Throttle Reactive Power, Phase B
nvoReactPowerPhC 63 Meter SNVT_power_f VAR 323 cpAllPower Throttle Reactive Power, Phase C
nvoAppPowerPhA 64 Meter SNVT_power_f VA 313 cpAllPower Throttle Apparent Power, Phase A
nvoAppPowerPhB 65 Meter SNVT_power_f VA 315 cpAllPower Throttle Apparent Power, Phase B
nvoAppPowerPhC 66 Meter SNVT_power_f VA 317 cpAllPower Throttle Apparent Power, Phase C